Tag Archives: Working platforms

Technical requirements for safety in metal scaffolding Appendix – Coverings for opening

Technical requirements for safety in metal scaffolding Appendix – Coverings for opening

  1. Coverings for opening

Every covering provided for an opening shall be

(a)    so  constructed  as  to  prevent  the  fall  of  persons,  materials  and

articles; and

(b)    clearly and boldly marked as to show its purpose or be securely fixed

in position.

 

Technical requirements for safety in metal scaffolding Appendix – Boards and planks in working platforms, gangways and runs

Technical requirements for safety in metal scaffolding Appendix – Boards and planks in working platforms, gangways and runs

  1. Boards and planks in working platforms, gangways and runs

Every board or plank forming part of a working platform, gangway or run shall

(a)    be of sound construction, adequate strength and free from patent

defect;

(b)     be of a thickness capable of affording adequate security having regard to the distance between the supports and be not less than

200 millimetres in width and not less than 25 millimetres in thickness or not less than 150 millimetres in width when the board or plank exceeds

50 millimetres in thickness;

(c)    not  protrude  beyond  its  end  support  to  a  distance  exceeding

150 millimetres unless it is sufficiently secured to prevent tipping;

(d)    rest securely and evenly on its supports; and

(e)     rest on at least 3 supports unless, taking into account the distance between the supports and the thickness of the board or plank the conditions are such as to prevent undue or unequal sagging.

Technical requirements for safety in metal scaffolding Appendix – Working platforms, etc. to be closely boarded

Technical requirements for safety in metal scaffolding Appendix – Working platforms, etc. to be closely boarded

  1. Working platforms, etc. to be closely boarded, etc.

(1)      Subject to subsection (2), every working platform, gangway and run shall

be closely boarded or planked.

(2)      Subsection (1) shall not apply to a working platform, gangway or run

(a)     consisting  of  open  metal  work  having  interstices  none  of  which exceeds 4 000 square millimetres in area; or

(b)     the boards or planks of which are so secured as to prevent their moving and so placed that the space between adjacent boards or planks does not exceed 25 millimetres.

if there is no risk of persons below the platform, gangway or run being struck by materials or articles falling through the platform, gangway or run.